AIR CONDITIONING

39

11.16 SAFETY TIPS FOR AC SYSTEM

Never handle refrigerant without eye

protection goggles. Don’t take chances.

Never discharge vapour from the system into

an area where there is flame.

Never close the compressor discharge valve

whilst the compressor is operating.

Discharge the air conditioning system slowly.

Never weld or steam clean on or near the

system. Doing so can result in dangerous

pressure build up in a closed system and a

possible rupture may occur.

Be careful when working near exposed

evaporator or condenser fins. Painful cuts

can be inflicted by these fins.

Keep your hands clear of the engine and

belts while the engine is running.

Installing Hoses and Fittings

1. Always use Refrigerant Oil not Motor Oil to

lubricate ID and OD of hoses and fittings

before installation

2. Use only refrigerant hose and fittings. When

installing new hose on old fittings, use same

type of hose to ensure proper mating of

hose and fittings