Background Image
Table of Contents Table of Contents
Previous Page  627 / 896 Next Page
Information
Show Menu
Previous Page 627 / 896 Next Page
Page Background

ELECTRICALS

125

Sr.

No.

Displayed

DTC Code

DTC Description

Fault

cause

Probable trouble Area

48 P0036 - 13

Downstream

oxygen

sensor

heater

control

circuit open

Circuit

open

1) Loose/ damaged connections or intermittent

fault.

2) Sensor supply line short circuit to battery/

ground.

3) Sensor signal line short circuit to battery/

ground.

4) Check the continuity from sensor connector

pins to the ECU pins.

5) Check for back out of pins at both sensor

connector and ECU connector.

6) Check for damage of pins at both sensor

connector and ECU connector.

7) Faulty downstream HO2S2 sensor.

8) Faulty ECU.

49 P0053 - 1B

Upstream oxygen

sensor

heater

resistance

too

high.

Circuit

resistance

above

threshold

1) Loose/ damaged connections or intermittent

fault.

2) Sensor supply line short circuit to battery/

ground.

3) Sensor signal line short circuit to battery/

ground.

4) Check for back out of pins at both sensor

connector and ECU connector.

5) Check for damage of pins at both sensor

connector and ECU connector.

6) Check the continuity from sensor connector

pins to the ECU pins.

7) Faulty HO2S1 sensor.

8) Faulty ECU

50 P0032 - 12

Upstream oxygen

sensor

heater

control short circuit

to battery

Circuit

short

to

battery

1) Loose/ damaged connections or intermittent

fault.

2) Sensor supply line short circuit to battery/

ground.

3) Sensor signal line short circuit to battery/

ground.

4) Check the continuity from sensor connector

pins to the ECU pins.

5) Check for back out of pins at both sensor

connector and ECU connector.

6) Check for damage of pins at both sensor

connector and ECU connector.

7) Faulty upstream HO2S1 sensor.

8) Faulty ECU.