ELECTRICAL
651
ELECTRICAL
CONDITION
POSSIBLE CAUSES
CORRECTION/REFERENCE ITEM
9. SIDE REPEATER LAMPS
Side repeater lamps not working 1) Connectors (2 pole) at the Connect the connectors properly.
lamps loose
2) Bulb loose/ blown
Fix the bulb properly. Replace bulb if
blown
3) Grounding point
Tighten grounding properly
10. REGISTRATION PLATE LAMPS
Single registration plate
1) Grounding point loose
Tighten grounding properly
lamp not working
2) Lamp connector loose
Fix connector properly
3) Bulb blown
Replace bulb
4) Parking lamp fuse (10A) in Fix the fuse in the base properly. If
cabin fuse box loose/blown blown, check for short in the circuit
and then replace the fuse.
Both lamps not working
1) Combi-switch faulty light
Replace combi-switch light stalk
stalk