GENERAL
3
1.2 PRECAUTION FOR ELECTRICAL
CIRCUIT SERVICE:
Disconnect the negative cable of the battery
while servicing the electrical parts that do not
require battery power and insulate the
negative terminal properly.
While removing the battery first disconnect
the negative cable and then the positive
cable. While reinstalling the battery, first
connect the positive cable and then negative
cable.
Be sure to turn the ignition switch off before
disconnecting and connecting coupler to
avoid electronic parts damage
Do not touch the electrical terminals of parts
which use microcomputers (e.g. electronic
control units like ECM etc.) to avoid damage
to these parts from static electricity from your
body
Always use the correct voltmeter, ohmmeter
for taking measurement to avoid damage to
the electronic control unit and sensors.
Make sure to insert the probe from wire
harness side of the connector for taking
measurement.
Make sure the connector halves are mating
properly and terminals seating precisely in the
connector body.
Dirt / corroded terminals result in improper
contact. The terminals should be cleaned
carefully.
Improper contact pressure between mating
terminals disturbs the connectivity between
them.
Replace the damaged connector body to
avoid exposure of the terminals in case of
inadequate contact pressure.