ALTROZ SERVICE MANUAL

TRANSAXLE - TA5260 50 11. Place the lay shaft assembly and input shaft assembly together along with shifter shaft assembly. 12. Place Reverse Idler Gear Assembly. 13. Tighten two hex screw & Fix the reverse lever bracket Assy. 14. Apply liquid gasket (Anabond 90 or 3 bond 12S00) with proper bead size on front half / rear half interface. NOTE: Clean the front half and rear half interfaces/ so that no cured and dried liquid gasket remained are left on the machined surfaces. 15. Fix the housing (rear half) and tighten the 14 outside flanged mounting bolts (M8x45) to specified torque. 16. Fix Reverse Idler Bolt M8x25. 17. Fix Snap Ring on Input shaft & Lay shaft Assembly. 18. Fix Detent Assembly on Shifter shafts.