FATC 22 D. MODE ACTUATOR. The actuator operates this flap in order to control the airflow direction inside the FATC unit. E.g., Chest, Demist or Defrost, Foot etc. NOTE: The actuators used to operate the doors are similar and can be interchanged. LOCATION PINOUT PIN NO DESCRIPTION 1 -ve (Ground) 2 feedback potentiometer 3 +ve 4 Not Used 5 +ve for CW & -ve for CCW 6 -ve for CW & +ve for CCW INSPECTION When 12.0V supply is given to pin 5 and pin 6, the movement of the actuator should follow the below table. Motor Movement Input Pin 5 Pin 6 Clockwise rotation + VE - VE Counter Clockwise rotation - VE + VE E. TEMPERATURE ACTUATOR The Actuator operates heater flap inside HVAC Unit, this flap diverts Hot & cold air inside HVAC Unit. LOCATION F. FRESH AIR / RECIRCULATION ACTUATOR