HVAC 39 D. BLOWER MOTOR REMOVAL AND ASSEMBLY 1. To access Blower from Driver side remove driver side Lower Panel. 2. Disconnect the clutch cable from clutch release lever. 3. Remove mountings on clutch pedal and take out the Clutch pedal. 4. Disconnect Electrical connection from Blower. 5. Remove one screws on blower Assembly. 6. Rotate the blower in anticlockwise direction and finally take out Blower motor Assembly. ASSEMBLY For assembly follow the reverse procedure of removal.