8. Remove the connector and cable of motor controller connected to 3in1 Unit Assy. 9. Remove HV Battery connector and cable from 3 in 1 combo unit assembly. Drain Coolant and remove Hose connection on 10. 3in1 Unit Assy. Remove the four screws mounted on the 11. bracket and safely remove the 3in1 Unit Assy having weight 12.5 kg. Fitment Follow reverse procedure for assembly. NOTE If any issues of DTC related to OBC, DC - DC Converter need to replace 3in1 Unit. For PDU/3in1 related DTC issue, PDU/3in1 serviceability need to perform. HIGH VOLTAGE ELECTRICAL SYSTEM (HV) 60