ALARM LIST FOR WMU ALARMS REASON LED INDICATION EPO Pressed Emergency button pressed by someone. Solid Red - Alarm NE Voltage High Neutral Earth voltage comes more than 10V or False read by charger or Phase-neutral terminal interchange. Blinking – Type 2 Red for 500 msec Earth Fault Earth Wire not connected/Phase- neutral terminal interchange Solid Red - Alarm RFID Comm Fail RFID Card stops communicating with the main Board or Energy meter not connected or energy meter addressing not done Blinking – Type 1 Red for 1 sec Earth Leakage Internally current leakage to earth or false reading CT damage or circuitry issue. Solid Red - Alarm O/P Current High When the load current increases from 32-35 A Blinking – Type 1 Red for 1 sec Mains Fail When the input voltage is not in its limit Blinking – Type 1 Red for 1 sec Mains Low When the input voltage is less than 150V Blinking – Type 1 Red for 1 sec Mains high When the input voltage is greater than 270V Blinking – Type 1 Red for 1 sec HIGH VOLTAGE ELECTRICAL SYSTEM (HV) 37