Insulated rescue hook: Insulated rescue hook should be placed near working area and should easily accessible • Incase of any person gets shock, other person should not touch with hands and pull the person who got • shock. Instated other person should pull the person who got shock with insulated rescue hook shown below. Lock out and tag out: In the workplace always have lock-outs on items with a potential safety concern. • Lock-out/de-energize high voltage equipment before debugging, working, or installing new equipment. • Ensure that only qualified people are working on the vehicle. • Minimizes the chance of injury for curious “passers-by” when nobody is around. • LOTO (Lockout, Tag-out) examples: Power source for equipment (line power, power supply, etc). • Authorized personnel: Only authorized personnel who are aware of the high voltage dangers should work • on HV equipment. HIGH VOLTAGE ELECTRICAL SYSTEM (HV) 5