HV ELECTRICAL SYSTEM_MR & LR 49 4. Insert The Screw For Bussbar And Ring Terminal And Tight It Partially This Is Only To Match Bussbar Hole 5. Plug The Screws Through The Bushing Holes Of The Ipt Housing Assy And Pre Screw Into The Interface Apply Recommended Torque Of 7 Nm 6. Tight Screw Of Bussbar As Shown Step 4 And Apply Recommended Torque Of 25 Nm 7. Close The Hv Terminal Cover And Tight The Screws. Apply Torque Value 6 Mm. Of In Diagonal Fashion For Screws Marked . NOTE HV Connector Removal Follow the reverse procedure of removal of HV connectors. G. PROCEDURE TO FIT BADA CONNECTORS TO 3IN1 COMBO BOX SETP-1 Hold the connector and Unlock the blue lock from connector lever by moving upward. Unlock the Lever Lock.