NEW NEXON SERVICE MANUAL

G. PRESSURE SENSOR PETROL 1. Discharge the refrigerant using standard recovering equipment. 2. Remove the Front Bumper.(Refer Exterior section) 3. Disconnect electrical connector. 4. Loosen & remove pressure sensor. H. HVAC UNIT REMOVAL 1. Discharge the refrigerant using standard recovering equipment. 2. Remove dashboard with cross car beam assembly. (For procedure, refer dashboard removal with cross car beam in body section.) 3. Disconnect all electrical connections. 4. Loosen and remove bolts and disconnect the inlet and outlet lines i.e. high pressure line and low pressure line and plug the ports. 5. Disconnect the Heater inlet and heater coil outlet pipes. WARNING The heater pipes contain hot coolant which • may spill out when disconnected, even if the coolant is drained, so be careful while disconnecting them. Keep a suitable container below it to collect • the coolant that will flow out. HVAC W/O ETC 49