5. Loosen the Ventilation Hose Clamp on HP Line and push down the corrugated / collapsible ventilation hose. 6. Make the Marking on the HP pipe connector & valve end connector. 7. Slowly loosen the coupling nut of inlet HP line at the cylinder valve, which connects the highpressure line to the connectors on the cylinder valve with 885554245801 Kit Swagelok Connector Wrenches. 8. Disconnect the inlet HP pipe from the cylinder valve. 9. Connect the 1/2 inch flexible pipe approx. 2 m length to the valve connector with cable tie & ensure proper fitment of flexible pipe .to release the gas in well-ventilated area. NOTE Use recommended tools to avoid damage to the CNG cylinder valve connector & HP pipe connector. 1.2L REVOTRON CNG PHASE-2 ENGINE 147