ALTROZ iCNG SERVICE MANUAL

Mounting Location: CNG Receptacle valve is fitted near petrol filling location under front bonnet. SR. NO. DISCRIPTION 1 DUST CAP 2 O-RING (9.13 × 2.62) 3 CIRCLIP FOR HOLE 4 FILTER WIREMESH 50 MICRON 5 BODY UPPER NGV-1 6 O-RING (10.78 × 2.62) 7 SPACER 8 BODY NRV 9 SPRING NRV 10 O-RING (9.13 × 2.62) 11 BODY LOWER NGV1 12 HEX NUT M22 × 1 (A/F 32) 13 SWAGELOK 1/4” NPT CONNECTOR SN TORQ UE KG FM THREAD SIZE REMARK 1 2.6-3.0 1/4” NPT Wrap 2 to 3 turns of Swaglok make Teflon tape on male threads of 1/4” OD Connector in clockwise direction, the first one or two threads of OD connector should be uncovered to avoid some part of Teflon tape going into adaptor. Do not reuse the same tape if external leakage is detected. 2 2.6-3.0 1/4” NPT 1.2L REVOTRON CNG PHASE-2 ENGINE 101

RkJQdWJsaXNoZXIy MTIwNTUz