NEXON EV MAX SERVICE MANUAL

LV ELECTRICAL SYSTEM 47 G. REGENRATION SWITCH 1. Level Down 2. Level Up Regeneration Operation  Regeneration is equipped in KANGER 2.0 EV, which converts the available kinetic energy during decelerating or braking condition of vehicle to electrical energy which can charge the High Voltage battery.  Regeneration level for the vehicle can be controlled manually or can be turned off.  By using the regeneration switch near to the PNRD rotary switch, driver can up/down regeneration level.  Level down switch can be used to reduce the regeneration level (3 to 2 to 1 to OFF).  Level up switch can be used to increase the regeneration levels (OFF to 1 to 2 to 3).  Default regeneration level on vehicle when vehicle is cranked will be Level1.  Regeneration will be reduced automatically when the high voltage battery is fully charged to prevent overcharging. Drive Modes Default Regeneration Levels SPORT LEVEL 1 CITY LEVEL 1 ECO LEVEL 1 Regeneration Levels Effect OFF No regeneration LEVEL 1 Minimum regeneration LEVEL 2 Intermediate regeneration LEVEL 2 Maximum regeneration Indicat ion at Cluster 1. CIRCUIT DETAILS 2. PINOUT DETAILS PIN DESCRIPTION 1 GND 2 Regeneration 3 PARKING - 4 PARKING +