NEXON EV SERVICE MANUAL

HV ELECTRICAL SYSTEM 61 8. Remove the mounting screw of heat exchanger of bracket. Fitment Follow reverse procedure for assembly. Tighten the following fasteners to the recommended torque. i) Compressor mounting. ii) Refrigerant lines on compressor. • Service and Maintenance Coolant drain and refill • Conduct activity when BCS pump is off • Remove cap of auxiliary tank • Remove one connection from battery inlet / outlet joint and drain the coolant. Refilling of coolant • Close all joints • Fill coolant from auxiliary tank • Follow de-aeration process. I. HV / LV CHARGER PORT & CABLE REMOVAL 1. Refer Instructions for working on HV Components mention before starting work. 2. Remove the connector and cable of HV charger to vehicle inlet connection connected to PDU. 3. Disconnect the cable connectors connected to the charger to vehicle inlet connection. 4. Pull out the fuel cap outside.