HV ELECTRICAL SYSTEM 54 bolts (4 per bracket) in diagonal fashion per bracket. Fasteners are to be pre-assembled in the sequence of : a. M10 bolt - 40 mm, 55 mm b. Spring Washer B10 c. 3D plain washer A10 4 Fastener assemblies with M10 x 40 mm bolts shall be assembled on mounting points 6, 7, 13 and 14. 10 Fastener assemblies with M10 x 55 mm bolts shall be assembled on rest of the mounting points. Once all the bolts are hand tightened and fitment is ensured, pack is ready to be mechanically torqued. Whilst torqueing, the bolts must be torqued in the following order to ensure correct fit of the battery pack – Tightening Torque 4.6 Kgf m (45 N m). - 06 & 13 - 14 & 7 - 05 & 12 - 08 & 1 - 02 & 9 - 11 & 4 - 03 & 10