TIAGO EV-SERVICE MANUAL

FITMENT Follow reverse procedure for assembly. Tighten the following fasteners to the recommended torque. i) Compressor mounting. ii) Refrigerant lines on compressor. Do’s and Don’ts Use only recommended refrigerant (R134a) • and correct charge quantity (490 gms) in the AC system Use only recommended lubricating oil for AC • compressor (Zerol Estar 68 oil) Ensure HV and LV connections of PTC heater • are properly connected Don’t remove connections of PTC heater when • it is working Always check coolant level in BCS tank • Avoid coolant leakage in BCS system • Do not change routing of coolant hoses. If hose • get pinch then coolant flow will be restricted leading to battery over heat. Compressor Speed Deration Strategies NOTE Always use compressor vibration dampers CA TE GO RY FAULT DESCRI PTION TH RE SH OL D DIAGNOSTI C STRATEGY REMA RK Ov er tem per atur e faul t Over temperat ure compress or slowdown (Deration-50 0 RPM each step) 95 °C As per temperature protection, the controller slows down the compressor speed once the temperature (IGBT) is higher than 95 °C After 7 cycles betwee n 105 and 95, compre ssors needs to be remove d and checke d In the field, a replac ed new compr essor does not reprod uce the error and works OK Over temperat ure compress or shutdown (CutOFF) 10 5° C The controller will stop the compressor when the temperature (IGBT) is higher than 105 °C Temperat ure protection removal (Recover y) 90 °C The temperature protection strategy is inactive when the temperature (IGBT) moves below 90 °C. After 30 seconds of temperature protection removal the compressor operates as per design intended VCU speed logic HIGH VOLTAGE ELECTRICAL SYSTEM (HV) 80