NEXON EV MAX SERVICE MANUAL

FATC 38 iii. CLOSED DOOR TEST INITIAL VEHICLE CONDITIONS Run the vehicle in the above condition with all doors closed for 10 min. At the end of 10 min insert the probe at the front vent and record the readings similarly insert the probe at the rear vent and record the reading. Closed Door Test Test Test Condition Ambient Temperature (°C) < 26 26 to 32 32 to 35 35 to 40 > 40 Stationary AC Performance Closed Door Test  Vehicle to be kept in shade  Test Duration-10 minutes  Vehicle Stationary All doors closed  Blower speed – Maximum  AC switch –ON  Temp Knob- Max Cool  Vent Mode- Chest  Air intake – Recirculation mode Note: ODCD test to be done at ambient temperature >20°C 12.2 10.4 10.8 11.5 12.4 Above data is for RH up to 40% For higher humidity, refer below graph For acceptable performance the measure grill temperature should lie on the line or below the line corresponding to RH