NEXON EV MAX SERVICE MANUAL

FATC 32 NOISE AND VIBRATION WHILE OPERATING A/C SYSTEM TROUBLESHOOTING HINTS  Noise when compressor running at higher speed-Step 1-2  Vibration when compressor running at higher speed-Step 3  Hose or refrigerant line interference noise -Step 4. STEP INSPECTION ACTION 1 Inspect oil quantity in the system. Check oil leakage from any joint of Ac system Yes Top up correct grade and quantity of oil No Go to next step 2 Compressor mounting need to check. Bracket mounting to be check. Yes Ensure proper tightening of all related fastener No Replace AC compressor 3 Inspect AC compressor interface vibration. Yes Check damper condition. Bolt tightening torque. No Go to next step 4 Inspect compressor Suction and Discharge pipe. Mounting clamps and rubber isolator. Yes Check compressor suction / discharge pipe, Its rubber isolator No Go to next step REFRIGERATION CYCLE TROUBLESHOOTING Sr. No. OCCURANCE POSSIBLE CAUSE REMEDY 1 Insufficient refrigerant Condition  Air conditioner does not cool effectively Symptoms in refrigerant cycle  Pressure on both the high and low pressure sides is low  Air around the air outlet is slightly cold Cause  There is gas leakage in the refrigerating cycle Diagnosis  Insufficient refrigerant in the refrigerating cycle  Refrigerant leakage Countermeasures  Locate the leakage and repair  Recharge refrigerant to the specified amount