HV ELECTRICAL SYSTEM 27 NOTE: Infotainment and cabin cooling can be used during charging of the vehicle by putting the vehicle in Ignition. 14. To stop the charging, switch off DC charging station. 15. The charging gun will be unlocked 15seconds after switching off the supply from DC charging station. 16. Put on the protective caps on both Charging Gun and Vehicle Inlet. NOTE: If you remove the charging gun from the vehicle and if you wish to reinsert the gun to recharge the vehicle, please wait for at least 10 seconds before charging gun is plugged again. In emergency charging shutdown conditions, Gun won’t be unlocked. Contact authorised TATA Service Centre. Action to be taken when charging stops abruptly Check the reason for interruption of charging. (Refer ‘Troubleshooting guide for Normal Charging’ table). Switch off the AC supply. Wait for 5 minutes. Restart the charging. (Refer charging procedure). Cleaning of Charging Inlet: Covering the charging gun and charging inlet by dust cap will ensure protection from water and dust. Precautions to be taken while cleaning the charging inlet: Keep the vehicle lid always closed. When the lid is open ensure that dust caps are in closed position. During normal charging, make sure that DC charging cap is closed. For any particle accumulation, blowing air should be done to clean the CCS2. No water or any liquids to be used. NOTE: Water entering into the charging port will always be drained through the drain system. If water is stagnant in charging port area call Tata Motors Authorised service centre to rectify the issue. FAST CHARGING ARCHITECTURE