ELECTRICAL 157 ELECTRICAL C.REMOTE LEARNING: SIGNAL LEVEL TYPE Battery Voltage High Input Key-In S/W High Input Ignition S/W High Input Crank S/W High Input Driver Door Unlock Low Input Co-Driver Door Unlock Low Input Remote Lock Button RF Input Remote Unlock Button RF Input Left Indicator Lamps PWM Output Right Indicator Lamps PWM Output Left 1ndication Tell Tale High Output Right Indication Tell Tale High Output Driver Door Unlock Relay Low Output All Doors Lock Relay Low Output Others Doors Unlock Relay Low Output LEARNING PROCESS OF NEW REMOTE AT USER END: 1. Driver door or co-driver door should be unlock, insert key into ignition barrel. Turn ignition “OFF to ON and ON to OFF” 4 times in 6 sec. Two flashes of left right indication lamps and tell tale O/P will be given. NOTE: If crank is made ON remote learning procedure will be canceled. 2. After two flashes, to learn the remote press lock and unlock button on remote simultaneously, within 10 sec. That remote will get learn with the BCM and all previously learnt remote will get unlearn. Left - right direction indicator lamp flashes twice. At the same time, door actuators move to lock position and back to unlock position, as a confirmation that remote is learnt. 3. To learn next remote repeat the step 2 within 10 sec. 4. Remote learning end with single long flash if, ignition is made ‘ON’ or 10 sec are over. NOTE: The timings mentioned in the procedures above has to be followed properly, otherwise the procedure has to be performed again. Maximum Four remotes can be learned with a single BCM.