GEAR BOX 6450 27 36. Remove the counter shaft bolt. CAUTION: Precaution to be taken while removing the counter shaft bolt to avoid the failure of bolt. 37. Mount the front housing puller as shown in figure. (Part No: 5403 5890 26 03). NOTE: Front housing removal puller bolts (4No’s) should be evenly tightened. 38. Remove the front housing by tightening the puller bolt. NOTE: Remove the hexagonal locking nuts, used for front housing locking before tightening of front housing puller bolts. 39. Remove the main shaft, drive shaft and counter shaft simultaneously with their forks from the intermediate plate. NOTE: After removing all shafts carefully place on table.