HVAC 76 ASSEMBLY 1. Align the projection of the field coil (1) to the pin hole of the compressor body (2) and then install the field coil. 2. Using snap ring pliers insert the snap ring to the field coil in correct orientation and check that it is properly installed. (Position tapered side to the face outside and put it in the groove.) 3. Fix wiring with the clamp. NOTE Apply torque of 0.196 Kg-m 4. While turning by hand, install the rotor gently. 5. Install the shim to the shaft. 6. Press-fit armature plate on to the shaft by taking care of the mating marks. Turn the rotor by hand to check for contact noise and smooth rotation. NOTE • The rotor should be free from abnormal noises when being turned by hand. • The rotor should be free from backlash. 7. Using the armature plate fixing tool (1), tighten the self-lock nut (4) by socket (14mm) (3) to the armature plate (2). NOTE Apply torque of 1.57 Kg-m 8. Check the air gap of the clutch using thickness gauge. If the air gap exceeds the range, of 0.2 to 0.45mm then remove the armature plate again and readjust the gap using shims. NOTE AIR GAP: 0.2 to 0.45mm