HVAC 67 6. Loosen and remove 3 mounting screws and take out the mode actuator assembly. 7. Loosen and remove 3 screws along with plastic washer and take out the linkage assembly (mode) from HAVC unit. 8. Loosen and remove 2 screws and take out the foot duct assembly. 9. Loosen and remove 2 screws and take out the BCM assembly. 10. Flip the HVAC assembly upside down to access the right hand side foot duct. 11. Loosen and remove 3 screws and take out the right hand side foot duct.