HVAC 4 SR NO. DESCRIPTION FASTENER TIGHTENING TORQUE (N-m) LOCATION 3B Condenser mounting M8 X 18 M8 X 30 12 ~ 14 12 ~ 14 4A Condenser seal assembly M5X16 6 ~ 8 4B Condenser assembly bolts M6X30 6 ~ 8