HEXA

HVAC 76 B TECHNICAL SPECIFICATION Fully Automatic control Panel Specs: Operating Voltage 9 to 16 V Operating Temp Range - 40 to + 85 °C Storage Temp. Range - 40 to + 85 °C Quiescent current < 1 mA Connector Type Connector J1 & J2 are a 16 –pole connector and shall be capable of interfacing with a 16-pole female connector The connectors J1 and J2 are keyed to avoid cross-insertion of the connectors. Input Signal Specifications: Battery Operating Voltage 9 to 16 v Current at ignition off < 1 mA Mode Actuator Feedback Type Linear potentiometer Voltage 4.7 V DC at maximum counterclockwise door flap rotation 0.2 to 4.7 V DC at intermediate door flap position 0.2 V DC at maximum clockwise door flap rotation Temperature actuator feedback Type Linear potentiometer Voltage 4.7 V DC at maximum counterclockwise door flap rotation 0.2 to 4.7 V DC at intermediate door flap position 0.2 V DC at maximum clockwise door flap rotation DIM Input PWM from BCM Module Duty cycle 20% to 100 % linear ramp up/down Voltage in low state ≤ 1 V Evaporator Temp Temperature range - 40 to + 85 °C Resistance Range 224 ohm to 80.37 K ohm Accuracy within operating range ± 5% Incar Temperature sensor Temperature range - 40 to + 85 °C Resistance Range 933.1 K ohm to 3.758 K ohm Operating Voltage 5 V Ambient Temperature sensor Temperature range - 40 to + 85 °C Resistance Range 321 ohm to 100.92 K ohm Operating Voltage 5 V Solar load sensor Temperature range -40 to + 90 °C Solar intensity 0 to 31.5 mW/cm² Operating Voltage 0 to 5 V Output Signal Specifications: Temp. Actuator Operating Voltage 12.5 Vdc Ign. Max Current ≤ 20 mA

RkJQdWJsaXNoZXIy MTIwNTUz