HVAC 68 B. REAR AC DISMANTLING 1. Push the stopper upward and rotate the blower in clockwise direction and remove the blower from AC assembly. 2. Loosen and remove Philips head mounting screws (7 Nos.) and take out the evaporator casing. 3. Loosen and remove mounting screws and take out the flap. 4. Remove the evaporator assembly from the casing. 5. Take out the TXV in the same manner as that removed in HVAC overhauling process. INSPECTION Refer the inspection points of AC system given for front HVAC assembly. ASSEMBLY For assembly follow the reverse procedure of removal.
RkJQdWJsaXNoZXIy MTIwNTUz