HVAC 17 B. FRONT HVAC UNIT The front HVAC unit in this Vehicle comprises of the following parts: i) Blower. ii) Blower Resister for Manual HVAC or LPM (Linear Power Module) for FATC systems. iii) Evaporator Coil iv) TXV v) Heater Coil vi) Air circulation ducts. i) BLOWER The Blower is located at the left bottom side of the HVAC unit when viewed from inside the car. It acts as a centrifugal pump drawing in air from the center and pushing it out diagonally. The air flows through the evaporator and the heater coil and then to the cabin. The Blower speed is controlled using a blower resister (in case of manual HVAC) or a Linear Power Module (in case of Fully Automatic Temperature Control (FATC))