HEXA

ELECTRICAL 25 REMOVAL: 1.Remove the Alternator belt (Refer alternator belt removal procedure). 2.Disconnect the electrical connection. 3.Loosen and remove the front mounting bolts (1) and the rear mounting bolt (2) to remove the Alternator (3). DISMANTLING PROCEDURE 1. REPAIR INSTRUCTIONS: 1.1 Dismantling of protective cap for OAP: To dismantle the inner Snapping Protective cap, the elastomer membrane is pierced with a sharp tool (Screw Driver) as shown in the fig. 1.2 Dismantling of Overrunning Pulley: Hold the alternator pulley by hand or with a pulley holder, using the serration tool overrunning alternator pulley can be unscrewed from the alternator shaft. NOTE: Assembly/dismantling tool is to be designed with serration in accordance to DIN 5487-7X20. Mounting chamfer in radial and axial are recommended in the area around the serrations. 1.3 Dismantling of Protective cap: Turn the alternator around and remove protective cap and nuts and remove the screw. Take off the Protection cap.