HARRIER SERVICE MANUAL PART -1

FATC 24 9. FATC SENSOR & ACTUATOR A. EVAPORATER SENSOR It is a temperature-sensing device, which is positioned at the coldest point of the evaporator (as shown in the fig below). The control unit switches OFF the compressor at a temperature when condensed water tends to form ice on the fins of evaporator. Thus it maintains the evaporator temperature within a specified range. LOCATION It is mounted on Air intake / Evaporator housing assembly. ON VEHICLE INSPECTION (WITHOUT DISMANTLING HVAC UNIT) Since the thermistor is mounted inside HVAC unit to conduct the above test HVAC unit has to be dismantled. Alternatively following test can be conducted without dismantling the HVAC unit: 1. Switch OFF the HVAC unit and allow the HVAC unit to come to ambient temperature. 2. Open the glow box & lowering Glove box lid. 3. Disconnect the Pigtail connections 4. Measure the resistance it should match to the ambient temperature. Refer graph in Inspection topic. As given in the graph above (~ 5 Ohms or less for ambient temperature of 25ºC and above)