NANO

TRANSAXLE 134 5. Seal the ‘Transmission Control Unit’ in correct ESD compliant bag closed by thermal welding and containing Silica Gel unit (for humidity absorbability). 6. Place the ‘Transmission Control Unit’ in an ESD proof package designed to protect connections, sensors and gasket from accidental contact. 7. ‘Transmission Control Unit’ should not be kept open exposed to the atmosphere for a longer time. This may damage the ‘Transmission Control Unit’. 8. The ‘Transmission Control Unit’ package must ensure protection against the accidental fall of tools or other pieces, in particular on the connectors and sensors. 9. Never use improper tool (screwdrivers, etc.) to lift and extract the ‘Transmission Control Unit’ from the electro valve block. 10. The surface of the electro valve block must be absolutely clean and free from oil or other polluting substances. Removal: 1. Disengage the female connectors with the cables from the ‘Transmission Control Unit’. 2. Unscrew the four ‘Transmission Control Unit’ fixing screws with sequence indicated below. NOTE Only these four screws are to be removed. Do not touch other screws. 3. In order to guarantee right ‘Transmission Control Unit’ translation during the dismounting, screw two 100 mm. length M5 ‘Special tool – guide rods’ in the holes previously used by ‘Transmission Control Unit’ fixing screws and shown in the picture below.

RkJQdWJsaXNoZXIy MTIwNTUz