NANO

HVAC 889 HVAC Inspection 1. Inspect condenser core fins for blockage or damage. Clogged condenser fins should be washed with water and should be dried with compressed water. Installation 1. Mount condenser assembly on locating lugs on body and tighten two nuts. 2. Connect Suction and Discharge lines. 3. Recharge the system using RRU. (Refer Refrigerant Recovery, Recycling and Recharging procedure) 4. Perform a leak test. (Refer Leak Test procedure) 5. Refit Front Bumper. (Refer Front Bumper installation procedure) Removal of condenser assembly 1. Recover the refrigerant using Refrigerant Recovery Unit (RRU) (Refer Refrigerant Recovery, Recycling and Recharging procedure) 2. Remove Front Bumper. (Refer Front Bumper removal procedure/Body group) 3. Disconnect suction (a) and discharge (b) lines from condenser assembly. NOTE: As soon as the refrigerant lines disconnected, cap the opened fittings so that moisture and dust do not enter into the system 4. Remove mounting nuts and take out condenser assembly. b a