880 HVAC 15.Remove four mounting bolts of cross beam member. (Two on each side) 16.Disconnect all electrical connectors of wiring harness and take out HVAC unit along with dashboard. 17. Remove two bolts securing HVAC unit to the dashboard and separate HVAC uni t from dashboard. NOTE: As soon as the refrigerant lines disconnected, cap the opened fittings so that moisture and dust do not enter into the system. 13.Disconnect heater lines. NOTE: As soon as the heater lines disconnected, cap the opened fittings so that moisture and dust do not enter into the system. 14.Remove two mounting nuts (located inside hood area) of HVAC unit.
RkJQdWJsaXNoZXIy MTIwNTUz