NANO

208 ENGINE 273 MPFI • Take out the new pre-calibrated Level Sensor Assembly from the cover. • Assemble the new pre- calibrated Level Sensor Assembly with the assistance of two locating pins provided on Level SensorAssembly and themating guiding holes provided on the Flange. • Press the new pre- calibrated Level Sensor Assembly unit you hear the click sound of clips being locked. Visually confirm clipping on flange • Reconnect the electrical connector of the Level Sensor Assembly. Ensure that blue wire is connected to S+ and black wire is connected to S- terminal. Assembly procedure: NOTE: • Spare level sensor assembly does not require calibration since it is precalibrated with master flange. • Do not handle the spare level sensor assembly by lever float assembly since it might lead to disturbance in calibration values due to any changes in the bend angles of the lever. • Hold the dissembled Level sensor Assembly Fuel Supply Unit upside down. Clip B Clip A

RkJQdWJsaXNoZXIy MTIwNTUz