FUEL SYSTEM 5 7. Remove tank filler hose and breather hose clamps Disconnect fuel filler hose and breather hose. 8. Remove three brackets supporting HVAC lines passing just below fuel tank. 9. Unscrew tank hexagonal mounting bolts and nuts of fuel tank mounting (Front and rear side). 10. Take out tank by tilting one end first and slide out through the gap between HVAC lines and chassis. Follow the reverse process for re-fitment of tank back to its position. WARNING A small amount of fuel may be released after fuel lines are disconnected. To avoid the chances of injury, cover the pipe to be disconnected with cotton cloth. Do not use cotton waste. To avoid damage to fuel / vapor hoses while disconnecting, slide back the clamps then twist the lines as you pull. When disconnecting fuel line quick connector, use shop towels to absorb fuel, protecting equipment and personnel, safety devices. INSPECTION: While removing fuel tank, check all hoses and pipes connected to fuel for leaks, loose connections, deterioration or damage. Replace if necessary. Check fuel module gasket for cracks etc after removal from fuel tank and replace if necessary. Visually inspect fuel tank for leaks and damage. Replace if necessary.