FUEL SYSTEM 6 CYLINDER VALVE MAINTENANCE PROCEDURE: There is no preventive maintenance require for Cylinder valve. However in case of damage of solenoid coil / valve due to certain adverse conditions, it may be necessary to replace the solenoid coil / valve. Solenoid coil / valve replacement procedure: Disconnect the electrical connections. Unscrew the fixing nut on top of the coil. Remove the coil / valve as shown and change it with the new one. CAUTION Always use only original valve / coil with proper specification. Apply lubricant Loxeal 85-21 on 2-3 threads of fixing nut and remove excess lubricant. Re-screw the fixing nut and tighten to a torque of 0.7 Kg-m. Re-connect electrical connection. 8