ZESTBOLT SERVICE MANUAL

AIR CONDITIONING 60 11.18.10 Diagnosis Trouble Codes B1F2B-12 Air Conditioning Compressor Request – circuit short to battery B1F2B-11 Air Conditioning Compressor Request – circuit short to Ground B1F3E-71 Temperature Door Control Motor - Actuator stuck B1F3E-54 Temperature Door Control Motor Calibration Fault B1F2D-12 Temperature Door Control Motor Drive Line - Circuit Short to Battery B1F2D-11 Air Temperature Motor Drive Line- Circuit Short to Ground B1F2D-13 Air Temperature Motor Drive Line- Circuit Open B1F47-13 Air Temperature Feedback Power Supply- Circuit Open B1F20-11 Air Temperature Feedback Power Supply- Circuit Short to Ground B1F20-12 Air Temperature Feedback Power Supply- Circuit Short to Battery B1F1F-15 Air Temperature Feedback Signal - Circuit Short to Battery or Open B1F1F-11 Air Temperature Feedback Signal - Circuit Short To Ground B1F2F-13 Blower Motor Drive Signal - Circuit Open B1F28-12 Blower Motor Diagnostic Feedback OR Blower Motor DTC - Circuit Short to Battery B1F28-14 Blower Motor Diagnostic Feedback - Circuit Short to Ground or Open B1F2F-12 Blower Motor Drive Signal - Circuit Short to battery B1F2F-11 Blower Motor Drive Signal - Circuit Short to Ground B1F2A-12 Cabin Temperature Sensor - Circuit Short to Battery B1F2A-14 Cabin Temperature Sensor - Circuit Short to Ground or Open B1F23-15 Evaporator Temperature Sensor Signal - Circuit Short to Battery or Open B1F23-11 Evaporator Temperature Sensor Signal - Circuit Short to Ground B1F46-13 Fresh Air/RECIRC Feedback Power Supply - Circuit Open B1F2C-13 Fresh Air/RECIRC Motor Drive Line- Circuit Open B1F2C-12 Fresh Air/RECIRC Motor Drive Line- Circuit Short to Battery B1F4B-56 BCM configuration Error- Invalid/Incompatible Configuration B1F2C-11 Fresh Air/RECIRC Motor Drive Line- Circuit Short to Ground B1F1E-12 Fresh Air/RECIRC Feedback Power Supply - Circuit to Battery B1F1E-11 Fresh Air/RECIRC Feedback Power Supply - Circuit Short to Ground B1F1D-15 Fresh Air/RECIRC Feedback Signal - Circuit Short to Battery or open B1F1D-11 Fresh Air/RECIRC Feedback Signal - Circuit Short to Ground B1F3F-71 Fresh Air/RECIRC Drive Motor – Actuator stuck B1F3F-54 Fresh Air/RECIRC Drive Motor – Missing calibration U161B-64 HuCCmConfigAck Data Mismatch or Not Received From HU - Signal Plausibility Failure B1F2E-12 Air Distribution Motor Drive Line– Circuit short to Battery B1F2E-11 Air Distribution Motor Drive Line– Circuit short to Ground B1F3D-54 Air Distribution Motor Drive Line– Missing calibration B1F3D-71 Air Distribution Motor Drive Line– Actuator stuck B1F22-12 Air Distribution Feedback Power Supply – Circuit short to Battery B1F22-11 Air Distribution Feedback Power Supply – Circuit short to Ground

RkJQdWJsaXNoZXIy MTIwNTUz