HVAC 15 1.1.5.2. HVAC UNIT The front HVAC unit comprises of the following parts: i) Blower ii) Blower Resister iii) Evaporator Coil and TXV iv) Heater Coil v) Air circulation ducts i) BLOWER The Blower is located at the right top side of the HVAC unit when viewed from inside the car. It acts as a centrifugal pump drawing in air from the center and pushing it out diagonally. The air flows through the evaporator and the heater coil and then to the cabin. The Blower speed is controlled using a blower resister.