NEXON

HVAC 2 THERMISTOR /THERMO AMPLIFIER NTC type ON setting 6.10 C ± 0.50 C OFF setting 4.10 C ± 0.50 C PRESSURE SWITCH / SENSOR Diesel Petrol Trinary Pressure Switch Linear Pressure Sensor coil voltage ( Applicable Voltage ) 8 V - 16V Pressure switch setting & type Low Pressure OFF 0.196 +/- 0.02 MPa ON 0.225 (+0.025, - 0.029) Mpa Middle Pressure OFF 1.52 +/- 0.15 MPa ON 2.01 +/- 0.1 MPa High Pressure OFF 3.14 +/- 0.2 Mpa ON (2.55) Mpa Current drawn Min operating current 10 mA FRESH AIR / RECIRCULATION MODE Actuator operated TEMPERATURE CONTROL Manual MODE CONTROL Manual BLOWER RESISTOR Plate Type BLOWER MOTOR IFB

RkJQdWJsaXNoZXIy MTIwNTUz