TIAGO/TIGOR AMT Gasoline DTC Troubleshooting Guide Version: 4.0 Date: 18-04-2017 Author: Sathi/Anupama Page: 275 of 427 Copyright © TATA MOTORS Ltd. This document must not be used in any way, such as copying and redistributing to third parties, without the consent of author. If the pump turns ON but no Pressure build up: 1> Check Kit oil, refill if necessary 2> Check for oil leakage / damage to hydraulic pipes. 3> Replace the TCU 4> Replace the Kit DTC’s confirmation:- After rectification, clear all DTC’s and ensure the following points by referring TCU parameters using TML diagnostic tool before handing over to customer.  Drive the vehicle through all gears in both Automatic and Manual modes  Ensure no DTC is active and Transmission Fault Lamp is OFF. Circuit Schematic Diagram: