HV ELECTRICAL SYSTEM 72 8. Remove the mounting screw of heat exchanger of bracket. Fitment Follow reverse procedure for assembly. Tighten the following fasteners to the recommended torque. i) Compressor mounting. ii) Refrigerant lines on compressor. • Service and Maintenance Coolant drain and refill • Conduct activity when BCS pump is off • Remove cap of auxiliary tank • Remove one connection from battery inlet / outlet joint and drain the coolant. Refilling of coolant • Close all joints • Fill coolant from auxiliary tank • Follow de-aeration process. I. HV / LV CHARGER PORT & CABLE REMOVAL 1. Refer Instructions for working on HV Components mention before starting work. 2. Refer Instructions of HV connector Lock removal process before starting work. 3. Open Fast Charger LID complete assembly. 4. Loosen and Remove two mounting screw of Fast Charger LID assembly and remove the assembly. 5. Remove mounting screw of Fast Charger LID Latch assembly. 6. Pull out Fast Charger LID Latch assembly along with Fast Charger LID Cable.