TIGOR EV_ZIPTRON_SERVICE MANUAL
HV ELECTRICAL SYSTEM 17 2 TYPES OF CHARGING Normal charging (AC charging) It takes about 8.5 hours at room temperature and normal operating conditions for the EV to charge from 10% to 90% with Normal Charging. The charging gun will be locked after switching on the AC supply. Fast charging (DC charging) EV vehicle can be fast charged using any fast charging station or equipment compliant to Combined Charging System standard having Type 2 connector (CCS Type 2). It takes 60 minutes for the high voltage battery to charge from 0% to 80% using any CCS Type 2 fast charging station. The charging gun will be locked after switching on the DC supply. NOTE: Battery performance and durability can deteriorate if the fast charger is used constantly. Use of Fast Charging should be minimized in order to help prolong high voltage battery life. After a maximum of four fast charging cycles of battery pack, it is recommended to use Normal Charging to achieve 100% State of Charge for optimum performance of high voltage battery pack. TYPRS OF CHARGING CHARGING SPECIFICATIONS CHARGE PORT CHARGE GUN POWER SOURCE Normal / AC Charging Nominal voltage: 230 V ac RMS Single phase, 50Hz supply. Voltage range : Minimum voltage = 190V ac RMS Maximum voltage = 250V ac RMS Power rating = 3kW as RMS Rated current 13A ac RMS. 3 pin wall socket Fast / DC Charging Nominal voltage: 320V DC. Charging station (CCS Type 2) voltage capability should be greater than or equal to 370V DC.