TIGOR EV SERVICE MANUAL
FATC 34 STEP INSPECTION ACTION 8 Verify whether malfunction is in expansion valve or receiver/drier. Turn A/C switch off and air conditioner stop for 10 minutes start turn both A/C switch and fan switch on. Does malfunction occur after compressor turn on? Yes Go to next step No Replace condenser and vacuum refriger- ant line more than 30 minutes by vacuum pump, and refrigerant to specified level. (Since water has intermixed in receiv- er/drier and it is saturated, replacement is necessary.) 9 Verify that expansion vale heat-sensing tube within cooling unit is positioned securely and correctly is expansion valve heat-sensing tube within cooling unit securely installed in proper position? Yes Replace expansion valve. (Since valve closes too much replacement is neces- sary.) No Install heat-sensing tube securely in prop- er position. 10 Inspect refrigerant lines inspect refrigerant lines Is piping free of damage and cracks? Are piping connections free of oil grime? (vis- ual inspection) Are piping installation points on a/c compres- sor free of gas leakage? Are piping installation on cooling unit free of gas leakage? Perform gas leak inspection using gas leak tester. Are above items okay? Yes Go to next step No If piping or an A/C component is damaged or cracked, replace it. 11 Inspect evaporator piping connections in cooling unit for gas leakage are piping connections for evaporator in cooling unit free of gas leakage? Yes If the vane makes a noise, add 10ml of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Adjust refrigerant to specified amounts. No If piping is damaged or cracked, replace it. If there is no damage, go to next step. 12 Inspect evaporator piping connections in cooling unit for looseness Yes Tighten connections to specified torque. If the vane makes a noise, add 10 ml of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Adjust refrigerant to specified amounts. No If the vane makes a noise, add 10 ml of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Replace O-ring on piping, adjust refriger- ant to specified amounts. 13 Inspect piping connections for looseness are piping connections loose? Yes Tighten connections to specified torque. If the vane makes a noise, add 10ml of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Adjust refrigerant to specified amounts. No If the vane makes a noise, add 10ml of compressor oil to the A/C compressor. Verify that the noise is no longer heard. Adjust refrigerant to specified amounts.
Made with FlippingBook
RkJQdWJsaXNoZXIy MTIwNTUz