TIGOR EV SERVICE MANUAL

LV ELECTRICAL 69 10. INSTRUMENT CLUSTER FEATURES Dynamic and monitoring information (e.g. Telltales, Speedometer & SoC Meter) to which the driver should respond, is indicated in the instrument cluster. The Instrument Cluster has following features:  Analogue Gauge : Speedometer and SoC gauge  Bar graph: Digital Efficiency Gauge  LCD Display : Clock, Odometer & Trip meter (A & B)  Tell tales  Mode & Set switches  Instrument Cluster BASIC ELECTRICAL SPECIFICATIONS: SR.NO . PARAMETERS SPECIFICATIONS 1 Nominal Voltage 13.5 V DC 2 Operating Voltage range 8 to 16 V DC 3 Test voltage 13.5 V DC 4 Boot-up time < 0.5 secs. 5 Operating Current 2 Amps. Max. @ all loads ON 6 Sleep mode (Ignition off) current < 1mA 7 Operating Temperature - 30°C to + 85°C 8 Storage Temperature -40°C to +85°C