FATC 52 7. Remove spring band clamps from coolant inlet outlet pipes of Chiller. 8. Remove Chiller mounting screw and take out Chiller. CAUTION Never leave chiller joints open, immediately cover with caps. Check condition of ‘O’ ring while re- assembly of AC pipes at Chiller TXV. FITMENT Follow the reverse procedure of removal. N. SOLENOID VALVE REMOVAL 1. Discharge refrigerant from AC system by using standard recovery instruments. 2. Remove electrical connection of solenoid valve. 3. Loosen two nuts of solenoid valve and take out valve from pipe. 4. Remove solenoid valve mounting nut on Body. FITMENT Follow the reverse procedure of removal.