ALTROZ SERVICE MANUAL

TRANSAXLE - TA5260 53 15. REMOVAL OF GEAR SHIFTER HOUSING, GEAR SHIFTER AND SELECTOR CABLE: 1. Ensure the gear lever in neutral condition. 2. Remove Lever knob, washer, cap screw and base plate. (Refer body section). 3. Remove the central floor console. (Refer body section). 4. Pry out both the cable lock plates and remove the cables from assembly gear shift housing. 5. Detach the selector cable and shift cable end from select lever ball. (Unlock yellow clip before Disassembly). 6. Unscrew the four bolts of gear shifter lever housing to remove it. 7. Pry out the shifter and selector cable ends from the transaxle housing. Slightly puts the wings by a finger and move upward cable end fitting. 8. Pull out the plunger from transaxle cable and remove it from the transaxle cable anchoring bracket. CAUTION: Pulling the cable end Fittings without unlocking the slider would bend the rod and damage the cable Assembly.