HVAC 20 Feedback Signal Values for Temperature Actuator Detent Position Knob Angle in Degrees (CW starting from the initial position) Voltage Min (V) Nominal (V) Max (V) 0 0 0.65 0.70 0.75 1 9 0.76 0.81 0.86 2 18 0.88 0.93 0.98 3 27 0.99 1.04 1.09 4 36 1.11 1.16 1.21 5 45 1.22 1.27 1.32 6 54 1.34 1.39 1.44 7 63 1.45 1.50 1.55 8 72 1.56 1.61 1.66 9 81 1.68 1.73 1.78 10 90 1.79 1.84 1.89 11 99 1.91 1.96 2.01 12 108 2.02 2.07 2.12 13 117 2.14 2.19 2.24 14 126 2.25 2.30 2.35 15 135 2.37 2.42 2.47 16 144 2.48 2.53 2.58 17 153 2.59 2.64 2.69 18 162 2.71 2.76 2.81 19 171 2.82 2.87 2.92 20 180 2.94 2.99 3.04 21 189 3.05 3.10 3.15 22 198 3.17 3.22 3.27 23 207 3.28 3.33 3.38 24 216 3.39 3.44 3.49 25 225 3.51 3.56 3.61 26 234 3.62 3.67 3.72 27 243 3.74 3.79 3.84 28 252 3.85 3.90 3.95 29 261 3.97 4.02 4.07 30 270 4.08 4.13 4.18