ALTROZ SERVICE MANUAL

1.5L REVOTORQ ENGINE 46 3. Insert the cone adapter with vacuum gun into the radiator filler neck (no loss tank) or coolant aux tank; make sure the refill hose valve is closed. 4. Turn on the air supply and Press the knob, allow the vacuum level to reach approximately 20-25 in Hg (50-60 cm Hg) and release the knob (The gauge reading may be slightly less in higher elevations but a proper vacuum should still be reached within 3 minutes). Let the system hold for 20 seconds to observe for a drop in vacuum. CAUTION  A drop in the gauge reading within 20 seconds indicates a vacuum leak in the system, which will require locating and rectifying the leakage before proceeding further. NOTE  During this procedure the radiator hoses will collapse under the vacuum being generated - this is normal.

RkJQdWJsaXNoZXIy MTIwNTUz