ALTROZ SERVICE MANUAL

FATC 44 4. Remove Mountings on Clutch Pedal. 5. Disconnect Electrical connection from Blower. 6. Remove one screw on blower Assembly. 7. Rotate Blower motor in anticlockwise direction and take it out. ASSEMBLY For assembly follow the reverse procedure of re- moval D. FRONT HVAC UNIT REMOVAL AND AS- SEMBLY 1. Recover the refrigerant using standard recovering equipment. 2. Remove dashboard Skin. (For procedure refer dashboard removal procedure in Body section.) 3. Disconnect all electrical connections. 4. Loosen and remove bolts and disconnect the inlet and outlet lines i.e. high pressure line and low pressure line and plug the ports. 5. Drain the coolant. 6. Disconnect the Heater inlet and heater coil outlet pipes. WARNING The heater pipes contain hot coolant which may spill out when disconnected, even if the coolant is drained, so be careful while disconnecting them. Keep a suitable container below to collect the cool- ant that will flow out. 7. Loosen and remove the mounting bolts of support tube on both side of HVAC unit and take out the tubes. 8. Loosen and remove mounting cap screws on HVAC lower mounting bracket as shown in figure below